With the 134-2, you get a high accuracy, mA Calibrator that is able to source and read from 0.00 to 24.00 mA, as well as simulate or simultaneously power and measure 2-wire transmitters to 14V DC. It may be pocketsized, but the 134-2 will drive into loads of up to 700Ω. The patented QUIK-CHEK switch allows you to instantly recall three pre-set output temperatures, and the display is able to be switched between either mA or a percentage of the 4 to 20 mA span.

Calibrate transmitters, recorders, controllers, alarms, indicators, process data acquistion and computer systems using the 134-2. The Altek 134-2 comes with a 3 year factory warranty, but based on the lifespan of units out in the market, this little calibrator could still be capable of doing the job well after you've retired!

Currently out of stock. Availability: 2 - 3 weeks

$1,372.00 +GST

Double click on above image to view full picture

Model 3331E-2
Manufacturer Altek
Manuf. Model 134-2
Manufactured In U.S.
Features
  • Sources and reads from 0.00 to 24.00 mA / -25.0 to +125.0%
  • Basic accuracy of 0.08%
  • Resolution of 0.01 mA
  • Simulates in loops powered from 3 to 45V DC
  • Powers and measures 2-wire transmitters to 14V DC
  • Drives up to 700Ω loads
  • Instantly outputs at three points from 0.00 to 24.00 mA
  • Speed sensitive digital potentiometer
  • Fuseless over-voltage protection to 120V AC / DC
  • Overload current protection to 25 mA
  • Operating temperature range of -20 to +55°C
  • Small and lightweight (weighs only 220g)
  • Optional soft carry case (see accessories)
Includes
  • Calibrator
  • Test leads (fixed)
  • Batteries (2 x 9V)
  • Instructions
  • Statement of calibration practices
Warranty
  • 3 years against defective materials and workmanship
  • Excludes batteries and leads
Returns Policy
  • Covered by our 7 day 'No Questions Asked' return guarantee
  • See our help section for full details

Check items to add to the cart or select all

  1. Altek 134-2 Loop Calibrator Nylon Case

Questions on Altek 134-2 Pocketcal mA Loop Calibrator

No questions asked yet

Please Sign up or Login to ask us a question about this product.

Write Your Own Review

Only registered users can write reviews. Please, log in or register